Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
F. The pressure switch or solenoid
vent valves inside the door are
not working.
F. Call the Customer Care Center
using the information provided on
the back page of this manual.
G. Error code in the controller has
been activated (beeping sound
is heard).
G1. Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
G2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
9. The bath will not drain or
drains slowly after
pressing the switch.
A. Tap toe drain will not open. A. Close and/or clean the toe tap
assembly. Reseal and reattach the
drain. Replace if needed.
B. The door switch is not being
pressed correctly.
B. Press the center of the door switch
button once lightly.
C. One or both drains are blocked. C. Remove the blockage.
D. The drain valve is connected to
another 120 V outlet and/or is
not plugged into the controller.
D. Plug the drain valve directly into J2
in the controller.
E. The drain valve is not working. E. Replace the drain valve or call the
Customer Care Center using the
information provided on the back
page of this manual.
F. Error code in controller has
been activated (beeping sound
heard).
F1. Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
F2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
G. There is a loose wire connection
in the door.
G. Call the Customer Care Center
using the information provided on
the back page of this manual.
Kohler Co. 43 1128532-2-G