Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms Probable Causes Recommended Action
C. The hot
and/or cold
supply hose
is kinked or
twisted.
C. Confirm the supply hoses are
not kinked or twisted. If coiled,
maintain an inside diameter of
3 (76 mm).
D. The outlet
hose is
kinked.
D. Confirm the solenoid valve is
located within 7 (178 mm) to
8 (203 mm) from the faucet
base.
E. One or more
screens are
clogged.
E. Refer to the Cleaning the
Screens section.
F. Cracked
diaphragm.
F. Replace the solenoid valve
assembly.
3. Poor spray
pattern.
A. The spray
nozzles are
clogged.
A. Rub your finger over the
nozzles with water running to
dislodge debris.
4. Circuit
board LED
is not lit.
A. No power to
the circuit
board.
A. Check the power supply
connections to the circuit
board.
B. Power cord is
plugged into
a switched
outlet.
B. Plug the power cord into an
unswitched 120 VAC outlet
(test the outlet with a radio or
other device). Confirm the
circuit board LED illuminates.
Solenoid Troubleshooting Table
Symptoms Probable Causes Recommended Action
1. Water
leaking
from the
valve.
A. Hose
connections
are not
secure.
A. CAUTION: Risk of personal
injury or product damage.
Turn off the main power and
water supply. Check all
connections. Make adjustments
as needed.
B. Internal leak. B. Replace the solenoid valve
assembly.
2. No audible
click
when
solenoid is
activated.
A. Loose
solenoid wire
connection.
A. Check solenoid wire
connection to the circuit board.
Kohler Co. 17 1186051-2-D